- Home
- Search Results
- Page 1 of 1
Search for: All records
-
Total Resources2
- Resource Type
-
0001000001000000
- More
- Availability
-
20
- Author / Contributor
- Filter by Author / Creator
-
-
Leddy, J. (2)
-
Hettige, C. (1)
-
Knoche, K.L. (1)
-
Moberg, P.D. (1)
-
Motsegood, P. (1)
-
#Tyler Phillips, Kenneth E. (0)
-
#Willis, Ciara (0)
-
& Abreu-Ramos, E. D. (0)
-
& Abramson, C. I. (0)
-
& Abreu-Ramos, E. D. (0)
-
& Adams, S.G. (0)
-
& Ahmed, K. (0)
-
& Ahmed, Khadija. (0)
-
& Aina, D.K. Jr. (0)
-
& Akcil-Okan, O. (0)
-
& Akuom, D. (0)
-
& Aleven, V. (0)
-
& Andrews-Larson, C. (0)
-
& Archibald, J. (0)
-
& Arnett, N. (0)
-
- Filter by Editor
-
-
& Spizer, S. M. (0)
-
& . Spizer, S. (0)
-
& Ahn, J. (0)
-
& Bateiha, S. (0)
-
& Bosch, N. (0)
-
& Brennan K. (0)
-
& Brennan, K. (0)
-
& Chen, B. (0)
-
& Chen, Bodong (0)
-
& Drown, S. (0)
-
& Ferretti, F. (0)
-
& Higgins, A. (0)
-
& J. Peters (0)
-
& Kali, Y. (0)
-
& Ruiz-Arias, P.M. (0)
-
& S. Spitzer (0)
-
& Sahin. I. (0)
-
& Spitzer, S. (0)
-
& Spitzer, S.M. (0)
-
(submitted - in Review for IEEE ICASSP-2024) (0)
-
-
Have feedback or suggestions for a way to improve these results?
!
Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
-
Simulations of cyclic voltammograms for a system with a spatially variant diffusion profile are presented. An expanded version of Fick’s Second Law is used to account for a diffusion coefficient that varies with x, distance normal to the electrode surface. Parameters to define the slope and magnitude of a linearly graded diffusion profile are described. A one dimensional explicit finite difference simulation method is used and parameters are made to be dimensionless. The simulation is vetted by comparison with Nicholson and Shain simulations and determination of the resolution limits. Morphological changes in cyclic voltammograms are observed that indicate an approach to steady state diffusion.more » « less
-
Motsegood, P.; Leddy, J. (, ECS transactions)A cyclic voltammetric measurement protocol for acetone concentration collected in the vapor phase and measured in solution is demonstrated for acetone concentrations across the human physiological range, 1 μM to 10 mM at platinum electrodes in 0.5M H2SO4. Effects arise through adsorption of acetone from the gas phase onto a platinum surface and hydrogen in acidic solution within the voltammetric butterfly region. The protocol is demonstrated to yield breath acetone concentration on a human subject within the physiological range and consistent with ketone urine test strip.more » « less
An official website of the United States government
